ECI MUX BG-20 PDF

4. nov Users Manual Generator ECI FUEL SYSTEMS than 15 ethanol blend or biodiesel blends in excess of B USER MANUAL BG 20 ECI MUX. BG 20 ECI Home · BG 20 ECI Eci TelecomBg Bg and Bg overview of eci adm APC ECM-ECI Error Codes Ver Codigos de Error. BGB/E. Miniature Optical Service Access Platform. Targeting a range of ECI Telecom Transport Networking Division’s BroadGate BGB (Basic unit) fulfills.

Author: Yoran Zologrel
Country: Ghana
Language: English (Spanish)
Genre: Sex
Published (Last): 1 May 2014
Pages: 354
PDF File Size: 8.86 Mb
ePub File Size: 19.10 Mb
ISBN: 622-1-27025-961-3
Downloads: 77460
Price: Free* [*Free Regsitration Required]
Uploader: Kagak

SM10E Slot Assignment window Select the Compare Result tab. The maintenance operations of the selected NE are listed in the display area.

Alarms include alarm generation, alarm clearance, and time interval information.

Timing configuration window – Timing Configuration tab Click Close to muc the confirmation window. Unmask the alarms when necessary to use these service ports. The Save and Apply operations can only be performed by an advanced operator or system operator.

To perform a card reset operation: The traffic here refers to the average traffic within the first 15 minutes in the acquisition process.

When using this function, the alarm status is not reported for ports not mix with traffic. Modify the VPN settings as needed and click Apply to save the settings. Port Connected Neighbor window History data for an alarm not reported automatically must be obtained using an alarm query. There are 13 existing To configure an aggregation group, you select a group andaggregation add ports togroups.

  D&D CITYSCAPE PDF

The frame then enters the filter processing. Select a card by selecting the relevant radio button.

In these cases, the fibers at some optical interfaces need to be removed because the signals at some optical interfaces are lost. Set the service type by selecting either the Working or Protection radio button. If successful, the Save operation automatically executes. Information window for setting the LCT work mode as monitor Click Query to display the data for this object, as reflected in the database. For example, 1 and 2, or 3 and 4, or 1, 2, 3, and 4 is permitted, and 3, 4, 5, and 6 is not permitted.

Orderwire Configuration window – Setting Orderwire Routing tab Select the Cold Reset or Warm Reset radio button. The supported trunk modes are: Orderwire Configuration window – Setting the Orderwire Attribute tab Changing this mapping influences the region definition. Port Attributes window for LAN ports In this window, four attributes can be configured and three are read-only.

BG 20 ECI – PDF Free Download

To clear NE alarm records: In a ring network, it is acceptable to perform this operation, as long as no two NEs employ a terminal loopback at the same time.

Therefore, the mapping should only be changed when the regions and trees are to be changed — not when a service is added. The Trunk Mode window opens. Stopped mode means the alarm log is no longer in use. Therefore, the NE equipment for which the alarms have been masked should have no alarm indication. The Please select the file window opens. Define the following card attributes and then click Apply for your changes to take effect: To sort current alarms: A cold reset resets not only the main processing unit but also the peripheral chips.

  HYPONATREMIA ADROGUE PDF

Import Trail From File window 2.

ECI BG 20/30 MUX – (2-Days)

Click Select File to select the filename to be downloaded, which appears in the field to the right. These XCs become Active after they are sent.

In the NE tree, select the card that needs a loopback and click Query to query the LCT-BGF database the about the loopback status of the timeslots belonging to this card. A warm reset has no influence on the service. Deactivating a client trail in Not All Active bb-20 sends the XCs included in it to the equipment and deletes these XCs in the equipment. When the NE performance monitoring switch is disabled, statistics collection on and monitoring of all performance objects in an NE are terminated.

To configure static IP routes: In addition, you can open the Timing Configuration window – Timing Maintenance tab on page from the main menu to view the current clock working mode and clock reference of the NE. This is used for selecting the root port or a designated port.